Delta CT2000 Series User Manual page 236

Table of Contents

Advertisement

Settings
Functions
7
Over Torque 1
8
Over Torque 2
9
Drive Ready
10
Low voltage warn (Lv)
11
Malfunction Indication
Mechanical Brake
12
Release (Pr.02-32)
13
Overheat
Software Brake Signal
14
Indication
15
PID Feedback Error
16
Slip Error (oSL)
Terminal Count Value
17
Attained (Pr.02-20; not
return to 0)
Preliminary Counter
18
Value Attained
(Pr.02-19; returns to 0)
External Base Block
19
input (B.B.)
20
Warning Output
21
Over-voltage Warning
Over-current Stall
22
Prevention Warning
Over-voltage Stall
23
prevention Warning
Operation Mode
24
Indication
25
Forward Command
26
Reverse Command
Output when Current >=
27
Pr.02-33
Output when Current <=
28
Pr.02-33
Output when frequency
29
>= Pr.02-34
Output when Frequency
30
<= Pr.02-34
Y-connection for the
31
Motor Coil
-connection for the
32
Motor Coil
Zero Speed (actual
33
output frequency)
Zero Speed with Stop
34
(actual output frequency)
Error Output Selection 1
35
(Pr.06-23)
Error Output Selection 2
36
(Pr.06-24)
Error Output Selection 3
37
(Pr.06-25)
Chapter 12 Description of Parameter SettingsCT2000 Series
Active when detecting over-torque. Refer to Pr.06-07 (over-torque
detection
level-OT1)
time-OT1). Refer to Pr.06-06~06-08.
Active when detecting over-torque. Refer to Pr.06-10 (over-torque
detection
level-OT2)
time-OT2). Refer to Pr.06-09~06-11.
Active when the drive is ON and no abnormality detected.
Active when the DC Bus voltage is too low. (refer to Pr.06-00 low
voltage level)
Active when fault occurs (except Lv stop).
When drive runs after Pr.02-32, it will be ON. This function should
be used with DC brake and it is recommended to use
contact "b"(N.C).
Active when IGBT or heat sink overheats to prevent OH turn off
the drive. (refer to Pr.06-15)
Active when the soft brake function is ON. (refer to Pr.07-00)
Active when the feedback signal is abnormal.
Active when the slip error is detected.
Active when the counter reaches Terminal Counter Value
(Pr.02-19). This contact won't active when Pr.02-20>Pr.02-19.
Active when the counter reaches Preliminary Counter Value
(Pr.02-19).
Active when the output of the AC motor drive is shut off during
base block.
Active when the warning is detected.
Active when the over-voltage is detected.
Active when the over-current stall prevention is detected.
Active when the over-voltage stall prevention is detected.
Active when the operation command is controlled by external
terminal. (Pr.00-20≠0)
Active when the operation direction is forward.
Active when the operation direction is reverse.
Active when current is >= Pr.02-33.
Active when current is <= Pr.02-33
Active when frequency is >= Pr.02-34.
Active when frequency is <= Pr.02-34.
Active when PR.05-24 is less than Pr.05-23 and time is more than
Pr.05-25.
Active when PR.05-24 is higher than Pr.05-23 and time is more
than Pr.05-25.
Active when the actual output frequency is 0. (the drive should be
at RUN mode)
Active when the actual output frequency is 0 or Stop.
Active when Pr.06-23 is ON.
Active when Pr.06-24 is ON.
Active when Pr.06-25 is ON.
12.1-02-13
Descriptions
and
Pr.06-08
(over-torque
and
Pr.06-11
(over-torque
detection
detection

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents