7-7 Digital Keypad
KPC-CE01
Key
ESC Key
ESC
Press ESC key to return to the previous page. It also functions as a return to last category key in the sub-menu.
Menu Key
Press MENU key under any condition will return to the main MENU.
MENU
Menu content:
1. Parameter Detail
2. Copy Parameter
ENTER Key
ENTER
Press ENTER and go to the next level. If it is the last level then press ENTER to execute the command.
HAND ON Key
1. HAND key will operates according to the parameter settings when the source of HAND master frequency
command and the source of HAND operation command is properly set,. The factory setting of the source
HAND
command for frequency and operation are from the digital keypad .
2. Press HAND key in stop status, the drive setting switches to the parameter setting of HAND. Press HAND
key in during operation, the drive will come to stop then switches to the parameter setting of HAND.
3. When process complete: H/A LED ON.
Auto Operation Key
1. AUTO function executes according to the parameter settings of the source of AUTO frequency and AUTO
operation. The factory setting is the external terminal (source of operation is 4-20mA).
AUTO
2. Press the ATUO key in stop status, the drivel switches to auto-setting. Press the auto key during operation
status, the drivel will come to stop and switch to auto-setting.
3. When process complete: H/A LED is OFF
Operation Direction Key
FWD/REV
1. FWD/REV key controls the operation direction but will NOT activate the drive. FWD: forward, REV: reverse.
2. The drive operates in the direction as shown by the LED light.
Start Key
1. It is only valid when the source of operation command is from the keypad.
RUN
2. Press the RUN key, the drive will according to the start-up setting and the RUN LED will be ON.
3. RUN key can be pressed for many times when the drive is in stop status.
4. "HAND" mode is enabled only when the source of operation command is by keypad.
Stop Key.
1. STOP key has the highest priority in command.
STOP
2. Press STOP key, the drive will come to stop under any condition.
3. The RESET key can be used to reset the drive when faults occur. If the RESET key is not responding, check
MENU  Fault Records and check the most recent fault.
A
: LED Disp lay
D ispla y freq uen cy, cu rre nt, vo ltag e and erro r etc.
: Status Indi cator
F: Fre que ncy C omma nd
H: Outp ut Frequ ency
U: User De fine d Uni ts
ERR: CAN Erro r Ind icator
RU N: CAN Ru n Indi ca tor
C
: Function
(Re fer to the chart foll ow s for deta il de scripti on )
Description
3. Keypad locked
4. PLC Function
7-15
Chapter 7 Optional AccessoriesCT2000 Series

Hide quick links: