Treatment for Encoder Feedback Fault
Settings
Detection Time of Encoder Feedback Fault
Settings
When encoder loss, encoder signal error, pulse signal setting error or signal error, if time exceeds
the detection time for encoder feedback fault (Pr.10-09), the encoder signal error will occur. Refer
to the Pr.10-08 for encoder feedback fault treatment.
Encoder Stall Level
Settings
This parameter determines the maximum encoder feedback signal allowed before a fault occurs.
(Max. output frequency Pr.01-00 =100%)
Detection Time of Encoder Stall
Settings
Treatment for Encoder Stall
Settings
When the motor frequency exceeds Pr.10-10 setting and detection time exceeds Pr.10-11, it will
operate as Pr.10-12 setting.
Encoder Slip Range
Settings
Detection Time of Encoder Slip
Settings
Treatment for Encoder Stall and Slip Error
Settings
Chapter 12 Description of Parameter SettingsCT2000 Series
0: Warn and keep operating
1: Warn and RAMP to stop
2: Warn and COAST to stop
0.0~10.0 sec
0: No function
0~120%
0: No function
0.0~2.0 sec
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
0~50%
0: Disable
0.0~10.0 sec
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
12.1-10-3
Factory Setting: 2
Factory Setting: 1.0
Factory Setting: 115
Factory Setting: 0.1
Factory Setting: 2
Factory Setting: 50
Factory Setting: 0.5
Factory Setting: 2