Delta CT2000 Series User Manual page 523

Table of Contents

Advertisement

Chapter 16 PLC Function CT2000 Series
API
INT
D
129
Bit device
X
Y
M
S
D
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
P
Word device
K
H
KnX KnY KnM
S: the source device to be transformed. D: results of transformation.
The content of the register designated by S is transformed from a binary
floating point number format into a BIN whole number, and is temporarily
stored in D. The BIN whole number floating point number will be discarded.
The action of this command is the opposite of that of command API 49
(FLT).
When X0=On, the binary floating point number (D1, D0) is transformed into a
BIN whole number, and the result is stored in (D10); the BIN whole number
floating point number will be discarded.
X0
Binary floating point number → BIN whole
number transformation
16-bit command
T
C
D
32-bit command (9 STEP)
DINT
execution type
Flag signal: none
DINT
16-82
Continuous
DINTP
execution type
D0
D10
Pulse

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents