Chapter 12 Description of Parameter SettingsCT2000 Series
Example: Crane Application
multi-function output
MO=42 (Active when
Fcom>=02-34, output
current>02-33 and time
>02-32)
It is recommended to be used with Dwell function as shown in the following:
Output Freq.
Multi-function output
MO= 42
( Activate when
Fcmd >= 02-34
output current > 02-33
Time > 02-32)
Multi-function Output Direction
Settings
 The setting of this parameter is in hexadecimal.
 This parameter is set via bit setting. If a bit is 1, the corresponding output acts in the opposite way.
Example:
If Pr02-13=1 and Pr02-18=0, Relay 1 is ON when the drive runs and is open when the drive is
stopped.
If Pr02-13=1 and Pr02-18=1, Relay 1 is open when the drive runs and is closed when the drive is
stopped.
Bit setting
bit15 bit14 bit13 bit12 bit11 bit10
MO20 MO19 MO18 MO17 MO16 MO15 MO14 MO13 MO12 MO11 MO10 MO2 MO1 Reserved RY2 RY1
Terminal Counting Value Attained (return to 0)
Settings
Output
Frequency
Freq. Command>02-34
& output current >02-33
Set 07-16=02-34and
output current >02-33
07-16 Dwell
Freq.
at Accel.
07-15
Dwell Time at Accel.
02-32
Brake Delay Time
0000h~FFFFh(0:N.O. ; 1:N.C.)
bit9
0~65535
12.1-02-16
02-32
Set 07-18=02-34 and
output current <02-57
bit8
bit7
bit6
bit5
Freq. command<02-58
or output current <02-57
02-32
07-18 Dwell Freq.
at Decel.
07-17
Dwell Time atDecel.
02-32
Brake Delay Time
Factory Setting: 0000
bit4
bit3
bit2
bit1 bit0
Factory Setting: 0