Delta CT2000 Series User Manual page 348

Table of Contents

Advertisement

I/F Mode, current command
Settings
PM Sensorless Obeserver Bandwidth for High Speed Zone
Settings
Reserved
PM Sensorless Observer Low-pass Filter Gain
Settings
I/F Mode, current command
Settings
I/F Mode, current command
Settings
PM Sensorless Control Word
Settings
Bit No.
0
Reserved
1
Reserved
2
Choose a control mode to
statrt.
3
Choose a mode to stop .
4
Reserved
5
Choose a control mode to stop 0 : When lower than Pr10-40, coast to stop
6
Reserved
7
Reserved
Reserved
Frequency Point when switch from I/F mode to PM Sensorless mode
Settings
Frequency Point when switch from PM Sensorless Observation mde to I/F mode
Settings
Chapter 12 Description of Parameter SettingsCT2000 Series
0~150%Irated (
Rated current % of the drive
0.00~600.00Hz
0.00~655.35Hz
0.00~3.00
0.00~3.00
0000~FFFFh
Function
0 :Start by IF mode
1: Start by VF mode
0 :Stop by IF mode
1 :Stop by VF mode
If lower than Pr10-40, decelerate to stop by VF mode.
0.00~599.00Hz
0.00~599.00Hz
12.1-10-7
Factory Setting: 40
)
Factory Setting: 5.00
Factory Setting: 1.00
Factory Setting:1.00
Factory Setting: 0.20
Factory Setting: 0000
Description
Factory Setting: 20.00
Factory Setting: 20.00