Battery; Service Specification; On-Vehicle Service; Fluid Level And Specific Gravity Check - Mitsubishi MOTORS Space Runner 1999 Workshop Manual Supplement

Hide thumbs Also See for Space Runner 1999:
Table of Contents

Advertisement

54-4

BATTERY

SERVICE SPECIFICATION

Item
Specific gravity of the battery fluid
Good
Thermometer
Hydrometer
CHASSIS ELECTRICAL –
Specification
1.220 – 1.290 [20 C]

ON-VEHICLE SERVICE

FLUID LEVEL AND SPECIFIC GRAVITY CHECK

1. Inspect whether or not the battery fluid is between the
UPPER LEVEL and LOWER LEVEL marks.
2. Use a hydrometer and thermometer to check the specific
gravity of the battery fluid.
Standard value: 1.220 – 1.290 [20 C]
The specific gravity of the battery fluid varies with the
temperature, so use the following formula to calculate
the specific gravity for 20 C. Use the calculated value
to determine whether or not the specific gravity is
satisfactory.
D20=Dt+0.0007 (t–20)
D20: Specific gravity of the battery fluid calculated
for 20 C.
Dt: Actually measured specific gravity
t: Actually measured temperature
Battery
54100030028
54100090071