Altitude
Humidity
Atmosphere
Climatic Conditions
Vibration
Safety
Overvoltage Category Overvoltage Category III
North America/ Canada Complies with the requirements of UL508C as an open-type drive.
890SD (Standalone) Drive: Frame G, H & J
If greater than 1000m above sea level, derate by 1% per 100m to a
maximum of 2000m
Maximum 85% relative humidity at 40°C (104°F) non-condensing
Non flammable, non corrosive and dust free
Class 3k3, as defined by EN50178
The product has been tested to the following specification:
Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Pollution Degree Pollution Degree II (non-conductive pollution, except for temporary
condensation)
Europe When fitted inside an enclosure, this product conforms with the Low
Voltage Directive 2014/35/EU using EN50178 to show compliance.

890 Operating Conditions