Technical Specifications
Electrical Ratings (Induction): 890SD Frame J, 400V
Power Supply = 380-500V ±10%, 50/60Hz 5%
Motor power, output current and input current must not be exceeded under steady state operating conditions.
Suitable for earth referenced (TN) and non-earth referenced (IT) supplies.
Model Number
(Europe)
Prospective short circuit current 100kA maximum.
FRAME J :
Constant Torque
Output Overload Motoring 150% overload for 60 seconds (all vector modes)
890SD-433590J..
Quadratic Torque
Output Overload Motoring 110% for 60s (V/Hz mode)
890SD-433590J..
E-14
Page
Catalog Number
Motor
Power
(North America)
315kW
890SD/4/0590J/..
500hp
355kW
890SD/4/0590J/..
550hp
Output
AC Input
Heatsink
Current
Current
Power
(A)
(A)
Loss (W)
(notes
1 & 2)
590
576
5788
590
584
650
642
6479
650
636
Total
Maximum
Input
Power
Switching
Bridge I
Loss
Frequency
(W)
(kHz)
(note 9
180% for 1s (V/Hz mode)
6260
2.5
813000
2.5
813000
6951
2.5
813000
2.5
813000