SKIP FREQUENCIES
SETUP::MOTOR CONTROL::SKIP FREQUENCIES
This function block may be used to prevent the Drive operating at frequencies that cause mechanical resonance in the load.
Parameter Descriptions
INPUT
The value of the block input in %.
BAND 1
The width of each skip band in Hz.
FREQUENCY 1
This parameter contains the centre frequency of each skip band in Hz.
BAND 2
The width of each skip band in Hz.
FREQUENCY 2
This parameter contains the centre frequency of each skip band in Hz.
BAND 3
The width of each skip band in Hz.
FREQUENCY 3
This parameter contains the centre frequency of each skip band in Hz.
BAND 4
The width of each skip band in Hz.
FREQUENCY 4
This parameter contains the centre frequency of each skip band in Hz.
D-144
Page
PREF: 91.01
PREF: 91.02
PREF: 91.03
PREF: 91.04
PREF: 91.05
PREF: 91.06
PREF: 91.07
PREF: 91.08
PREF: 91.09
Default: 0.00 %
Default: 0.0 Hz
Default: 0.0 Hz
Default: 0.0 Hz
Default: 0.0 Hz
Default: 0.0 Hz
Default: 0.0 Hz
Default: 0.0 Hz
Default: 0.0 Hz
890SD Standalone Drive - Frames G, H & J
Range: -300.00 to 300.00 %
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 Hz