Encoder Lines - Parker AC890 Product Manual

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

REFERNCE ENCODER
SETUP::PHASE CONTROL::REFERNCE ENCODER
This block is used to set up how the reference encoder input is obtained, via the Reference Encoder Speed Feedback Option
Card. This option card can be fitted to the control board in either position, upper or lower. The drive must be capable of using
the High Performance blocks found in the DSE 890 Configuration Tool.
Various encoder types may be selected (including pulse encoder, sincos encoder and absolute single-turn or multi-turn) and
require different hardware options. If an encoder type is selected which does not match the hardware, an error will be flagged.
The reference encoder input will normally be used to make the drive precisely follow an external reference. This is done in
conjunction with the VIRTUAL MASTER function block. The Firewire mode must first be selected. The parameter
VIRTUAL MASTER :: SOURCE should be set to REFERNCE ENCODER. The virtual master output will then be equal to
the reference encoder input.
Parameter Descriptions
PULSE ENC VOLTS
Set this approximately to the supply voltage required by the pulse encoder.
SINCOS ENC VOLTS
Used to set the supply volts required by the sin/cos encoder.
Enumerated Value : SinCos Encoder Volts

ENCODER LINES

The number of lines must be set to match the type of encoder being used. Incorrect setting of this parameter will result in an
erroneous speed measurement.
D-120
Page
PREF: 158.01
PREF: 158.22
0 : 5V
1 : 10V
PREF: 158.02
Default: 10.0 V
Default: 5.0 V
Default: 2048
890SD Standalone Drive - Frames G, H & J
Range: 10.0 to 20.0 V
Range: See below
Range: 250 to 262143