COMMS CONTROL

SETUP::SEQ & REF::COMMS CONTROL
This block switches between Remote Terminal and Remote Comms operating modes.
The Drive must be in Remote mode for selection to be made - REMOTE mode is enabled in the LOCAL CONTROL function
block (REF MODES) and selected by the keypad. Refer to the outputs of the LOCAL CONTROL function block for the mode
in use.
Parameter Descriptions
REMOTE COMMS SEL
Selects the type of remote communications mode:
0 : FALSE, and in REMOTE mode then control is from the terminals.
1 : TRUE, and in REMOTE mode then control is from the communications.
FIREWIRE REF SEL
This parameter selects Firewire Ref as the active reference.
REMOTE SEQ MODES
Selects the type of remote sequencing mode:
Enumerated Value : Mode
REMOTE REF MODES
Selects the type of remote reference mode:
Enumerated Value : Mode
D-18
Page
PREF: 95.01
PREF: 95.10
PREF: 95.02
0 : TERMINALS/COMMS
1 : TERMINALS ONLY
2 : COMMS ONLY
PREF: 95.03
0 : TERMINALS/COMMS
1 : TERMINALS ONLY
2 : COMMS ONLY
Default: FALSE
Default: FALSE
Default: 0
Default:0
890SD Standalone Drive - Frames G, H & J
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: Enumerated - see below
Range: See below