Parker AC890 Product Manual page 39

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

890SD Standalone Drive
Main Cooling Fan and Supply Requirements
The Frame G and H drives have an integral main cooling fan. However, the Frame J drive has a separate
main cooling fan which must be fitted to the bottom panel of the enclosure as shown in drawing
HG465731U001 at the end of this chapter, with the 4 off M6 nuts provided. Refer to drawing
HG463151D002 for fan wiring details (Frame J only) in Chapter 10: "Routine Maintenance and Repair" –
Fan Replacement.
The drives require an external single phase supply and fuse protection (motor start type) for the main
cooling fan.
Drive
Frame G
<=132kW / 200HP
Frame G
>132kW / 200HP
Frame G
>132kW / 200HP
Frame H
Frame J
4-20
Page
Airflow
Part Number
(cfm / m
DL389775
350/595
DL464085
350/595
DL465651U115
475/807
DL465651U230
475/807
DL471062U115
475/807
DL471062U1230
475/807
DL389776U001
883/1500
DL464086U001
883/1500
DL389776U001
1032/1753
DL464086U001
1032/1753
Supply Volts
Watts
3
/hr)
115
205
230
195
115
315
230
330
115
405
230
355
115
560
230
520
115
600
230
560
890SD (Standalone) Drive: Frame G, H & J
Fuse
3A
2A
4A
2A
5A
3A
8A
4A
10A
5A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

890sd

Table of Contents