DISPLAY SCALE

SETUP::MENUS::DISPLAY SCALE
These function blocks, 1 to 4, can be used to display any floating point parameter with an applied scaling factor, formulae and
your preferred units.
PREF 65.xx is DISPLAY SCALE 1, PREF 66.xx is DISPLAY SCALE 2, etc.
Parameter Descriptions

DECIMAL PLACE

Select the position of the decimal point.
Enumerated Value : Position
FORMULA
Select a formula where A, B and C are the coefficients listed below, and X is the value to modify.
Enumerated Value : Formula
890SD Standalone Drive - Frames G, H & J
PREF: 65.01, 66.01, 67.01,
68.01
0 : DEFAULT
1 : X.XXXX
2 : X.XXX
3 : X.XX
4 : X.X
5 : X.
PREF: 65.02, 66.02, 67.02,
68.02
0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
Default: 0
Default: 0
Range: Enumerated - see below
Range: Enumerated - see below