Parameter Descriptions
TEST DISABLE
This parameter expands on the MMI to show five tests. Each test can be individually disabled by setting to TRUE.
Enumerated Value : Test
SPD LOOP BNDWDTH
Sets the target bandwidth for the speed loop autotune. After the speed loop autotune, this will display the actual bandwidth
corresponding to the speed loop gains.
SPD MAX TORQUE
Sets the maximum torque that will be used in the speed loop autotune test.
SPD MAX SPEED
Sets the maximum speed that will be used in the speed loop autotune test
ACTIVE
This indicates the current state of the Autotune sequence. The Autotune sequence is operational when displaying TRUE.
890SD Standalone Drive - Frames G, H & J
PREF: 80.03
0 : STATOR RES
1 : LEAKAGE IND
2 : ENCODER DIR
3 : MAG CURRENT
4 : ROTOR TIME CONST
PREF: 80.20
PREF: 80.23
PREF: 80.24
PREF: 80.09
Default:
Default: 2.0 Hz
Default: 50.0 %
Default: 50.0 %
Default:
Range: 0 to 4
Range: 0.0 to 500.0 Hz
Range: 0.0 to 500.0 %
Range: 15.0 to 100.0 %
Range: FALSE / TRUE