Parker AC890 Product Manual page 569

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

Technical Specifications
Electrical Ratings (Servo): 890SD Frame H, 400V
Power Supply = 380-460V ±10%, 50/60Hz 5%
Motor power, output current and input current must not be exceeded under steady state operating conditions.
Suitable for earth referenced (TN) and non-earth referenced (IT) supplies.
Model Number
(Europe)
FRAME H :
Prospective short circuit current 100kA maximum.
Quadratic Torque
Output Overload Motoring 110% for 60s (PMAC mode)
890SD-433375H..
890SD-433420H..
890SD-433480H..
890SD-433520H..
E-18
Page
Catalog Number
Motor
Power
(North America)
250kW
890SD/4/0375H/..
400hp
250kW
890SD/4/0420H/..
400hp
300kW
890SD/4/0480H/..
450hp
315kW
890SD/4/0520H/..
500hp
Output
AC
Heatsink
Current
Input
Power
(A)
Current
Loss (W)
(A)
(notes
1 & 2)
343
450
4704
480
461
383
450
4704
383
461
428
545
5317
428
529
465
571
5761
465
581
Total
Maximum
Input
Bridge I
Power
Switching
Loss
Frequency
(W)
(kHz)
(note 9)
5092
4
813000
2.5
813000
5092
4
813000
4
813000
5743
4
813000
4
813000
6200
4
813000
4
813000