Parameter Descriptions
ACCELERATION
The acceleration at which the distance is added to the phase loop, set in units per second
ACTIVE
Active is set TRUE whenever the block is enable, i.e. the move distance is none zero..

DISTANCE LEFT

A diagnostic showing the distance remaining before the move is complete.
OFFSET
This diagnostic shows the total position offset generated by the move block. (1.0 = 1 load mechanical revolution)
Functional Description
This is a simple trapezoidal relative move function, which acts on each rising edge of the
Enable input. The slave shaft is moved a fixed distance at a rate given by the VELOCITY
parameter. A move must be complete before a new move will be registered.
890SD Standalone Drive - Frames G, H & J
PREF: 109.07
PREF: 109.05
PREF: 109.06
PREF: 109.10
Default: 1.00 %
2
.
Default: FALSE
Default: —.xx
Default: —.xxxx
Range: 0.01 to 300.00 %
Range: FALSE / TRUE
Range: —.xx
Range: —.xxxx
Distance
Velocity