MOTOR PMAC 1
SETUP::MOTOR CONTROL::MOTOR PMAC 1
Designed for PMAC Control Mode.
The MOTOR PMAC blocks (1 & 2) store all the parameters needed to run a PMAC Motor. These parameter values are entered
automatically by the DSE 890 Configuration Tool when the tool is used to select the motor type.
In order for the drive to control the motor the parameters marked ● MUST be set.
Parameter Descriptions
MANUFACTURER
Enter the motor manufacturer's name.
MODEL
Enter the motor name.
● CONSTRUCTION
Select the motor's construction type.
Enumerated Value : Construction
ATMOSPHERE
Select the motor's atmospheric details.
Enumerated Value : Atmosphere
890SD Standalone Drive - Frames G, H & J
PREF: 134.01
PREF: 134.02
PREF: 134.03
0 : AXIS
Standard motor.
1 : SPINDLE
Spindle motor.
2 : TORQUE
Direct torque motor.
PREF: 134.04
0 : STANDARD Standard motor.
1 : EXPLOSIVE Motor built for explosive atmosphere (Ex).
Default: PARVEX
Default: HS620EV
Default: 0
Default: 0
Range:
Range:
Range: See below
Range: See below
D-83