The Keypad
The L/R Key
1
The L/R key (LOCAL/REMOTE) toggles between Remote and Local Mode. In doing so, the view of the
SETPOINT parameter in the OPERATOR menu toggles between SETPOINT (LOCAL) and SETPOINT
(REMOTE). The default is for the SETPOINT (REMOTE) parameter to be displayed.
Note
A different naming convention is applied in the OPERATOR menu for these parameters when displayed
as the first parameter entry:
• REMOTE SETPOINT is displayed as SETPOINT (REMOTE)
• LOCAL SETPOINT is displayed as SETPOINT (LOCAL)
• COMMS SETPOINT is displayed as SETPOINT (COMMS)
• JOG SETPOINT is displayed as SETPOINT (JOG)
Pressing the L/R key when in Remote mode takes you directly to the SETPOINT (LOCAL) parameter with
the Edit mode enabled. Press the PROG key to return to the previous display.