Parker AC890 Product Manual page 218

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

6511
6901
Keypad
Keypad
Display
Display
FERR
FIRMWARE ERROR
RSLV
RESOLVER ERROR
MI2T
I2T MOTOR TRIP
STO
SAFE TORQUE OFF
REFC
REF ENCODER CAL
REFF
REF ENCODER FAIL
DCFG
DRIVE CONFIG ERR
CT1
CUST TRIP 1
CT2
CUST TRIP 2
890SD Standalone Drive - Frames G, H & J
Description
See function block
description
See function block
description
-
The drive has failed to set
absolute position
-
Drive configuration error
See function block
description
See function block
description
Trips and Fault Finding
Possible Reason for Trip
 The firmware in the drive has stopped executing
 Motor current is too high
 Motor is undersized
 Function not implemented
 Check the encoder supports absolute position, and
that the encoder is wired correctly.
 Function not implemented
 The configuration defined in DRIVE CONFIG
doesn't match the actual drive configuration.