Parameter Descriptions
SPEED FBK RPM
This parameter changes according to the CONTROL MODE (DRIVE CONFIG function block):
 In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per minute as
calculated from the speed feedback device.
 In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per
minute.
 In VOLTS/Hz mode the parameter shows motor synchronous speed in rpm.
 In PMAC control mode, the parameter shows the mechanical speed of the motor shaft.
SPEED FBK REV/S
This parameter changes according to the CONTROL MODE (DRIVE CONFIG function block):
 In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per second as
calculated from the motor speed feedback.
 In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per
second.
 In VOLTS / Hz mode, the parameter shows the motor synchronous speed in revolutions per second.
 In PMAC control mode, the parameter shows the mechanical speed of the motor shaft.
890SD Standalone Drive - Frames G, H & J
PREF: 70.04
PREF: 70.05
Default: —.xx rpm
Default: —.xx rev/s
Range: —.xx rpm
Range: —.xx rev/s