Parker AC890 Product Manual page 576

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

Internal Dynamic Brake Switch (Frame G)
Motor
Brake Switch
Power
Peak Current
(kW)
380-460V ±10%, 45-65Hz
DC link brake voltage: 750 - 820V
180
Internal Dynamic Brake Switch (Frame H)
Motor
Brake Switch
Power
Peak Current
(kW)
380-460V ±10%, 45-65Hz
DC link brake voltage: 750 - 820V
280
890SD (Standalone) Drive: Frame G, H & J
Peak Brake
Dissipation
(A)
(kW/hp)
20s maximum, 30% duty
360
270/360
Peak Brake
Dissipation
(A)
(kW/hp)
20s maximum, 30% duty
560
420/560
Technical Specifications
Brake Switch
Continuous Brake
Continuous
Dissipation
Current
(kW/hp)
(A)
72
54/72
Brake Switch
Continuous Brake
Continuous
Dissipation
Current
(kW/hp)
(A)
112
84/112
Minimum
Brake Resistor
Value
()
2.08
Minimum
Brake Resistor
Value
()
1.34