Parker AC890 Product Manual page 63

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

890SD Standalone Drive
4-Q
PMAC
4-44
Page
Set-up using 4Q Regen Active Front End (AFE) control mode.
4-Q REGEN
Refer to Chapter 7 to correctly set-up the drive for an 890CD/SD 4-Q Regen
AFE Application.
Autotune is not required.
Set-up using PMAC (Permanent Magnet AC) servo or torque motor control
PMAC
mode - a high performance application where the drive uses Resolver or
Sin/Cos Encoder motor feedback.
In this mode, speed feedback signals from the motor shaft encoder are
processed to determine the rotational speed of the shaft. A PI algorithm within
the software uses this information to produce varying gate drive signals to the
drive circuits. These signals cause the drive to output the required voltage and
frequency for a particular motor speed.
Autotune is not required.
The Motor Selection Wizard in the 890 DSE Configuration Tool MUST be
used to correctly set-up the motor and feedback device parameters. Failure to
do so may result in damage to the servo motor.
Control Modes
890SD (Standalone) Drive: Frame G, H & J

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

890sd

Table of Contents