Functional Description
This block defines the parameters needed to build the following curve. It is used to limit the motor's
current, depending on the speed.
PERM CURRENT
CURRENT AT MPS1
CURRENT AT MPS2
CURRENT AT MPS3
STAND CURRENT
If the motor permanent current is defined as a constant on the whole range of use, the following parameters
must be set to :
- MPS1 = MPS2 = MPS3 = AC input voltage (in Vrms)
- CURRENT AT MPS1 = CURRENT AT MPS2 = CURRENT AT MPS3 = PERM CURRENT from
MOTOR PMAC 1 function block
- SPEED AT MPS1 = SPEED AT MPS2 = SPEED AT MPS3 = MAX SPEED from MOTOR PMAC 1
function block
D-90
Page
CURRENT = f (SPEED ) or I = f ( N )
LOW SPEED VALUE
SPEED AT MPS1
SPEED AT MPS2
SPEED
SPEED AT MPS3