Parameter Descriptions
INIT DONE
This is a diagnostic output indicating the state of the resolver init sequence:
INIT DONE = FALSE : init on going
INIT DONE = TRUE : init done
REVERSE CNT DIR
Set the count direction for the resolver feedback.
REVERSE CNT DIR = FALSE : the position is increasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
REVERSE CNT DIR = TRUE : the position is decreasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.

SPEED FILTER

No action
PHASE SHIFT
No action
TRIP SELECTION
Select the trip detection based on hardware and/or software detection:
Enumerated Value : Trip Selection
890SD Standalone Drive - Frames G, H & J
PREF: 133.17
PREF: 133.18
PREF: 133.19
PREF: 133.20
PREF: 133.21
0 : HARD AND SOFT
1 : HARD
2 : SOFT
Default: TRUE
Default: FALSE
Default: 100.00
Default: 0.00
Default: 2
The trip is based on hardware and software detection.
The trip is only based on hardware detection.
The trip is only based on software detection.
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: 10.00 to 1000.00 Hz
Range: 0.00 to 180.00°
Range: See below