Parameter Descriptions
DIST TO MASTER
This diagnostic displays the distance (1.0 = 1 load mechanical revolution) between the load shaft position and the Master
Position + Total Offset position.
ACTIVE
This diagnostic is TRUE to indicate Move to Master is active.
STATE
This diagnostic indicates the state of the Move to Master move.
Enumerated Value : State
D-92
Page
PREF: 124.06
PREF: 124.08
PREF: 124.09
0 : RESET
the move to master is in a reset state and cannot be used.
1 : READY
the move to master is ready to be enabled
2 : POS AQUIRE the target position for the move is being acquired
3 : ALIGN
the move is active
4 : DONE
the move to master is complete
Default: —.xxxx
Default: FALSE
Default: 1
Range: —.xxxx
Range: FALSE / TRUE
Range: See below