Parker AC890 Product Manual page 432

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

Parameter Descriptions
TRIPPED
Indicates that there is a latched trip present.
RUNNING
Indicates that that the Drive is in the enabled state.
JOGGING
Indicates that the Drive is in the JOG mode.
STOPPING
Indicates that the Drive is stopping.
OUTPUT CONTACTOR
Output to be used to drive an external contactor in the motor output. This contactor is normally closed unless a Trip condition
has occurred or the Drive goes into the re-configuration mode.
SWITCH ON ENABLE
Sometimes referred to as READY TO SWITCH ON, this parameter indicates that the Drive will accept a run command.
SWITCHED ON
Run accepted. Waiting for CONTACTOR CLOSED and any motor deflux delay to be completed
READY
Indicates that the Drive's power stack is operable and the Drive will run if enabled.
SYSTEM RESET
TRUE for a single block diagram execution cycle after the Drive enters either RUN or JOG mode.
890SD Standalone Drive - Frames G, H & J
PREF: 92.13
PREF: 92.14
PREF: 92.15
PREF: 92.16
PREF: 92.17
PREF: 92.18
PREF: 92.19
PREF: 92.20
PREF: 92.21
Default: FALSE
Default: FALSE
Default: FALSE
Default: FALSE
Default: FALSE
Default: FALSE
Default: FALSE
Default: FALSE
Default: FALSE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
Range: FALSE / TRUE
D-141
Page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

890sd

Table of Contents