Parker AC890 Product Manual page 452

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

SPEED LOOP 2
SETUP::MOTOR CONTROL::SPEED LOOP 2
Designed for SENSORLESS VEC and CLOSED-LOOP VEC Motor Control Modes.
There are three filters operating on the speed loop torque demand output. They add compensation to the transfer function of the
motor and load. This can improve performance. Use the tuning tool in the DSE 890 Configuration Tool to set these filters
optimally.
Setting the Filter Type to NONE will cause the filter to have no effect. If compensation is required, up to three filters may be
selected in any order and in any combination.
One of the filters is located in the SPEED LOOP function block, the other two filters are located in the SPEED LOOP 2
function block (this block).
 The SPEED LOOP function block contains one filter: this is selected by COMPENSATION F1 and COMPENSATN TYPE
(a second parameter COMPENSATION F2 is also used when the compensation type is selected to be PHASE ADVANCE).
 The SPEED LOOP 2 function block (this block) contains two filters: these are selected by TQ COMP 2 FREQ and
SELECT TQ COMP 2, and also TQ COMP 3 FREQ and SELECT TQ COMP 3.
Parameter Descriptions
SELECT TQ COMP 2
Selects the type of compensation applied to the torque demand. Refer to Functional Description in the SPEED LOOP
function block for selection details. (PHASE ADVANCE is not selectable with this filter)
Enumerated Value : Filter Type
890SD Standalone Drive - Frames G, H & J
PREF: 163.1
0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
Default: NONE
Range: See below
D-161
Page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

890sd

Table of Contents