890CD Common Bus Drive & 890SD Standalone Drive
PREF
6901 Display
27.02
POWER
27.03
MOTOR BASE
FREQ
(induction
motor
only)
27.04
* MOTOR
VOLTAGE
(induction
motor
only)
27.07
* NAMEPLATE RPM This parameter contains the motor nameplate
(induction
motor
only)
27.09
MOTOR POLES
(induction
motor
only)
890SD Standalone Drive - Frames G, H & J
QUICK SETUP MENU
Description
Nameplate motor power.
The output frequency at which maximum
voltage is reached.
This parameter contains the motor nameplate
voltage at base frequency
full-load rated speed. This is the motor speed
in rpm at base frequency minus full load slip
This parameter contains the number of motor
poles, as supplied on the motor nameplate
Keypad Menus
Range
0.0kW to 3000.0kW
7.5 to 1000.0 Hz
0.0 to 575.0V
0.0 to 30000.0 RPM
0=2 pole
1=4 pole
2=6 pole
3=8 pole
4=10 pole
5=12 pole
Default
product
code
dependent
50.0 Hz
product
code
dependent
product
code
dependent
1
8-24
Page