Parker AC890 Product Manual page 408

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

Parameter Descriptions
MAX SPEED
The maximum speed clamp and scale factor for other speed parameters. 100% speed = maximum speed in rpm.
SPEED DEMAND
Indicates actual speed demand to the Drive after reference ramp.
SPEED SETPOINT
Indicates target speed. This will be equal to either LOCAL SETPOINT, REMOTE SETPOINT, JOG SETPOINT, COMMS
SETPOINT or FIREWIRE SETPOINT before reference ramp. (Refer to the REFERENCE JOG function block for the JOG
SETPOINT parameter).
REVERSE
Indicates demanded direction. This may not be the actual direction as no account of setpoint sign is taken.
LOCAL SETPOINT
Indicates the Keypad setpoint. It is always a positive quantity; saved on power down. Direction is taken from LOCAL
REVERSE.
LOCAL REVERSE
Indicates demanded direction in Local Reference mode, saved on power down.
COMMS SETPOINT
This setpoint is the target reference that the Drive will ramp to in Remote Reference Comms mode (not including trim). A
positive value indicates a forward direction.
FWIRE SETPOINT
This diagnostic shows the Firewire Ref speed setpoint.
SPEED DEMAND
Indicates actual speed demand to the Drive after reference ramp.
890SD Standalone Drive - Frames G, H & J
PREF: 101.08
PREF: 101.09
PREF: 101.10
PREF: 101.11
PREF: 101.12
PREF: 101.13
PREF: 101.14
PREF: 101.15
PREF: 101.16
Default: 1500 rpm
Default: —.xx %
Default: —.xx %
Default: FALSE
Default: —.xx %
Default: FALSE
Default: 0.00 %
Default: —.xx %
Default: —.x Hz
Range: 0 to 32000 rpm
Range: —.xx %
Range: —.xx %
Range: FALSE / TRUE
Range: —.xx %
Range: FALSE / TRUE
Range: -300.00 to 300.00 %
Range: —.xx %
Range: —.x Hz