Technical Specifications
External AC Supply (RFI) Filter (Part Number CO467843U340)
The drive can be supplied with filters to meet the 'industrial' Class A conducted emission limits of EN55011 when used with
50m of screened motor cable and the specified 3% minimum AC line choke as listed below.
Frame
Motor
Number
Size
Power
of Filters
(kW)
Required
in
Parallel
G
110
1
G
132
1
G
160
2
G
180
2
H
200
2
H
220
2
H
250
2
H
280
2
J
315
2
Filters suitable for earth referenced (TN) supplies only. The filter is suitable for use at 3kHz switching frequency only.
E-22
Page
Phase Watt
Leakage
Loss
Current
(W)
(mA)
3
50
>100mA
3
50
>100mA
3
100
>100mA
3
100
>100mA
3
100
>100mA
3
100
>100mA
3
100
>100mA
3
100
>100mA
3
100
>100mA
Current
Maximum
Supply
Performance
(A)
Voltage
(V)
(Industrial)
340
460
Class A
340
460
Class A
340
460
Class A
340
460
Class A
340
460
Class A
340
460
Class A
340
460
Class A
340
460
Class A
340
460
Class A
EMC
Maximum
AC Line Choke
Motor
Class
Cable
Length (m)
50
CO389936U401
50
CO389936U401
50
CO389936U402
50
CO389936U402
50
CO389936U402
50
CO389936U402
50
CO389936U403
50
CO389936U403
50
CO389936U403