890CD Common Bus Drive & 890SD Standalone Drive
PREF
70.03
This shows the rms voltage, between phases, applied by the drive to the motor terminals.
99.06
A read-only parameter indicating the state of the dynamic brake switch.
73.04
The drive output frequency in Hertz.
97.05
Indicates which trips are currently active. These parameters are a coded representation of the trip status.
97.06
Indicates which trips are currently active. These parameters are a coded representation of the trip status.
97.09
From when a trip occurs until that trip is reset, this parameter indicates the trip source. When several trips have
occurred, this parameter indicates the first one that was detected.
890SD Standalone Drive - Frames G, H & J
DIAGNOSTIC MENU
6901 Display
TERMINAL VOLTS
(Refer to the FEEDBACKS function block)
BRAKING
(Refer to the DYNAMIC BRAKING function block)
DRIVE FREQUENCY
(Refer to the PATTERN GEN function block)
ACTIVE WORD 1
(Refer to the TRIPS STATUS function block)
ACTIVE WORD 2
(Refer to the TRIPS STATUS function block)
FIRST TRIP
(Refer to the TRIPS STATUS function block)
Keypad Menus
Range: —. V
Range: FALSE / TRUE
Range: —.x Hz
Range: 0000 to FFFF
Range: 0000 to FFFF
Range: Enumerated - refer to block