Parker AC890 Product Manual page 187

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

Keypad Menus
890CD Common Bus Drive & 890SD Standalone Drive
PREF
78.20
The demanded motor torque as a percentage of rated motor torque.
70.10
The estimated motor torque, as a percentage of rated motor torque.
70.11
A value of 100% indicates the motor is operating at rated magnetic flux (field).
70.12
This diagnostic contains the level of rms line current being drawn from the drive and is seen as a % of the
MOTOR CURRENT parameter setting in the MOTOR INDUCTION function block.
70.13
This diagnostic contains the level of rms line current being drawn from the drive.
70.02
The internal dc voltage tested across the DC link capacitors.
8-11
Page
DIAGNOSTIC MENU
6901 Display
TORQUE DEMAND
(Refer to the SPEED LOOP function block)
TORQUE FEEDBACK
(Refer to the FEEDBACKS function block)
FIELD FEEDBACK
(Refer to the FEEDBACKS function block)
MOTOR CURRENT %
(Refer to the FEEDBACKS function block)
MOTOR CURRENT A
(Refer to the FEEDBACKS function block)
DC LINK VOLTS
(Refer to the FEEDBACKS function block)
Range: —.xx %
Range: —.xx %
Range: —.xx %
Range: —.xx %
Range: —.x A
Range: —. V
890SD Standalone Drive - Frames G, H & J