Trips and Fault Finding
6511
6901
Keypad
Keypad
Display
Display
STLL
MOTOR STALLED
IT
INVERSE TIME
DB R
BRAKE RESISTOR
DB S
BRAKE SWITCH
DISP
OP STATION
SCI
COMMS BREAK
9-6
Page
Description
The motor has stalled (not
rotating)
External dynamic braking
resistor has been overloaded
Internal dynamic braking
switch has been overloaded
Keypad has been
disconnected from drive
whilst drive is running in
local control
Possible Reason for Trip
Motor loading too great
Current limit level is set too low
Stall trip duration is set too low
Fixed or auto boost levels are set too high
The inverse time current limit is active: motor loading
is too great; fixed or autoboost levels are too high
(Full Load Current = 150% for 60 seconds)
Trying to decelerate a large inertia load too quickly or
too often
Trying to decelerate a large inertia load too quickly or
too often
Keypad accidentally disconnected from drive
COMMS BREAK parameter set to True (refer to I/O
TRIPS menu at level 3)
890SD Standalone Drive - Frames G, H & J