Parker AC890 Product Manual page 457

Frame g, h & j
Hide thumbs Also See for AC890:
Table of Contents

Advertisement

Parameter Descriptions
Enumerated Value : Source
ENCODER LINES
Sets the number of lines of the simulated encoder.
DIRECTION
Allows inverting the synthetic encoder direction with regards to the source direction.
Enumerated Value : Direction
Z PULSE OFFSET
Sets the position in degrees at which the marker pulse (Z pulse) occurs.
D-166
Page
0 : V MASTER POSN
1 : FBK ENCR SHAFT
2 : FBK ENCR LOAD
3 : REF ENCR SHAFT
4 : REF ENCR LOAD
PREF:160.02
PREF:160.03
0 : SAME AS SOURCE
1 : REVERSE OF SRCE
PREF:160.05
Default:1024
Default: SAME AS SOURCE
Default:0.000 deg.
890SD Standalone Drive - Frames G, H & J
Range: 4 to 65536
Range:See below
Range: 0.0000 to 360.000
deg.