Dc2+Pi Application Change - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

17.7
Common Commands
for All Languages
17.7

DC2+PI Application Change

Application Change
Command
DC2
HEX code
<12>
16
Default Value
None
When turning off the power switch
Valid range
Printer operation in progress
Valid range and
term of
Error
command
Others
[Function]
This command is used to switch applications such as SBPL and SZPL.
[Format]
DC2 (12H) + PI,aa
[Parameters]
Symbol
Parameter name
Identifier
aa
[Return data format (normal)]
[ACK]<06>
16
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Exception processing]
Parameter name
Identifier
Terminology
Command error
Invalid receive data
[Supplemental explanation]
1. Setting value of the printer will be switched when switching the application. So, obtaining and saving the setting of the
application before switching, then switching it,and then put it back to the original application, after that set it by
previously saved settings, and it performs the operation before switching it.
e.g.)When switching the application such as SBPL - STCL - SBPL
1) Obtain and save the setting value of SBPL state (obtain the setting value by AIOT, [DC2]PB[EOT] and so on)
2) Switch the application to STCL.
3) Switch the application to SBPL.
4) Set the setting value obtained and saved in the step 1).
2. Please send this command in a state which the printer is not working anything in Offline or Online standby state
waiting state.
The result of this command sent in pause status during cancellation is not guaranteed. In such case, restart the
printer.
3. AUTO mode will not be available unless you reboot after switching to AUTO mode.
The printer works with the application before the change until it reboots.
PI
<50>
<49>
16
16
Valid range
00:AUTO
SB: SBPL
SZ: SZPL
SI: SIPL
SD: SDPL
ST: STCL
SE: SEPL
Exception condition
A value outside the range is
specified
Command error
Description
The data received after a command error is determined is not
considered as a parameter of this command.
The data corresponding to Byte 2 and thereafter of the identifier is
ignored.
Parameter
,aa
The command cannot be received during the printer
operation. ([NAK] return)
The command cannot be received while an error is
occurring. ([NAK] return)
Commands cannot be received other than when the
screen is Online or Offline. ([NAK] return.)
Acquisition method
Two characters fixed acquisition
The specified size and received
size are different
Invalid receive data
439
DC2+PI

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents