Esc+Ip0 Epc Code Write(Uhf) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

16.1 RFID
16.1

ESC+IP0 EPC Code Write(UHF)

EPC Code write(UHF)
Command
ESC
HEX code
<1B>
16
Default Value
Nil
When turning off the power switch
Valid range and
term of
Valid range within item
command
Valid range between items
[Function]
This command writes the EPC code and other data to the EPC corresponding RFID tag. The standard format
(three-character parameter identifier) is used when using the memory area extended for each IC chip manufacturer.
Available in M6e module installed printers.
[Format]
[Standard format]
<IP0>e:h(,pcw:xxx)(,epc:xxxx...xxxx)(,usr:xxxx...xxxx)|(,usa:dddd,aaaaa...aaaa)(,lck:bbbbb);
[Conventional format]
<IP0>e:a,c:d,s:d,d:ddddddddddddd(,o:xxx)(,m:bbbbb)(,k:xxxxxxxx)(,a:xxxxxxxx)(,p:xxxxxxxx);
<IP0>e:c,f:d,c:d,t:d,d:ddddddddddddddddd,n:dddddddddddd(,o:xxx)(,m:bbbbb)(,k:xxxxxxxx)(,a:xxxxxxxx)
(,p:xxxxxxxx);
<IP0>e:z(,d:xxxxxxxxxxxxxxxxxxxxxxxx)(,u:xxxxxxxxxxxxxxxx)(,k:xxxxxxxx)(,a:xxxxxxxx)
(,p:xxxxxxxx)(,o:xxx)(,m:bbbbb)(,k:xxxxxxxx)(,a:xxxxxxxx)(,p:xxxxxxxx);
Note: Typical parameters are shown in the format examples above. Refer to the next item for details on the
parameters.
[Conventional format] is solely for maintaining compatibility with models before CL4NX. If you are going to use a
new command from CL4NX and beyond, please create with [Standard format].
●Parameter
EPC encode type parameter
EPC encode
Type
e:
Specify the
parameter right after
<IP0>.
The parameter
cannot be omitted.
IP0
Parameter
<49>
<50>
<30>
See under "Parameters".
16
16
16
The set command is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
[Standard format]
Use the three-character parameter identifier after the declaration.
h
The memory area extended for each IC chip manufacturer can be
extended for other than the standard Gen 2 tag.
[Conventional format] SSCC96 code conversion
Use the "one-character parameter identifier".
a
When the Company prefix/Serial reference/Filter value is
received, and then converted to an SSCC96 compliant code, and
written to the tag.
[Conventional format]SGTIN96 code conversion
Use the "one-character parameter identifier".
c
When the Company prefix/Serial reference/Filter value is
received, and then converted to an GTIN96 compliant code, and
written to the tag.
[Conventional format] Free mapping
z
Use the "one-character parameter identifier".
When data is written as is without performing code conversion.
313
ESC+IP0
[SSCC96 code conversion]
[SGTIN96 encoding]
[Free mapping]