17.15
Common Commands
for All Languages
17.15

DC2+PK IDm Return(FeliCa)

IDm return(FeliCa)
Command
DC2
HEX code
<12>16
Default value
None
When turning off the power switch
Valid range
Valid range and
term of
Printer operation in progress
command
Error
[Function]
Returns the result of writing to RFID tag using <RK> command together with a 64-digit hexadecimal numeric sequence
as a result of IDm+PMm+ID block
[Format]
[DC2]PK
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d[CR][LF][ETX]
[Return data]
Symbol
Parameter name
Total number of data byte
* This is the total number of bytes after parameter b.
a
The delimiting comma between parameters a and b,
and the ETX are not included.
Write result status
*Text format
b
Error symbol
c
IDm return data
d
PK
Parameter
<50>16<4B>16
None
The command cannot be received during the printer
operation. ([NAK] return)
Commands can be received even if an error is occurring.
465
DC2+PK
Valid range
Data size from the first write result
status until before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
Note: Specified in text format.
N:No error
I:IDm read error
A:All errors
Note: Specified in text format
Refer to 【 IDm return data】 as
below