5.2 Control
5.2

ESC+Z Stop Code

Stop Code
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying the end of data transmission.
[Format]
<Z>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
1. Indicates the end of item and to be placed at the tail of item.
2. Use Start of Data Transmission <A> and <Z> as a pair of commands.
[Note]
If this command is not specified, printing will not be performed.
Z
Parameter
<5A>
Nil
16
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.
11