7.7.1.2
Status 3 (when CRC check is enabled)
Host
CONNECT
Status
Print command (STX-ETX CRC)
Status
Print command (STX-ETX CRC)
Status
~ ~
DISCONNECT
ENQ
(Status request command)
ID Number = [Space]
Status = "Waiting for receive"
Remaining print q'ty = [000000]
ID number = [05]
Printq'ty = 100
ACK
(Printer status: no error)
ENQ
(Status request command)
ID number = [05]
Status
Status = "Editing"
Remaining printq'ty = [000000]
ENQ
(Status request command)
ID number = [05]
Status = "Printing"
Remaining print q'ty = [000100]
ID number = [06]
Print q'ty = 50
ACK
(Printer status: no error)
ENQ
(Status request command)
ID number = [05]
Status = Paper end
Remaining print q'ty = [000098]
(Status request command)
ENQ
ID number = [05]
Status = "Printing"
Remaining print q'ty = [000098]
Status
ENQ
(Status request command)
ID number = [05]
Status = "Printing"
Status
Remaining print q'ty = [000001]
ENQ
(Status request command)
ID number = [06]
Status = "Printing"
Status
Remaining print q'ty = [000050]
Printer
Receive/Analysis/Edit
Print operation
Print the 1st label
Print the 2nd label
Print the 3rd label
Print the 3rd label
~ ~
~ ~
Print the 100th label
Print the 1st label
572
Receive/Analysis/Edit
Paper end error