NXP G2XL dedicated secure parameters (can be omitted)
(Cannot be used in a Gen2 chip other than NXP G2XL.)
rlk:
Read protection
G2X,
eas:
EAS bit data
G2X,
NXP G2iM/G2iL dedicated secure parameters (can be omitted)
(Cannot be used in a Gen2 chip other than NXP G2iM/G2iL.)
rlk:
Read protection
G2I,
eas:
EAS bit data
G2I,
Feed control parameters (can be omitted)
fsw:
Feed without printing
SSCC96/SGTIN96 standard code conversion parameters
Declaration of code
enc:
standard conversion
flt:
Filter value
com:
Company prefix
srl:
Serial reference
Item reference
itm:
(Only for SGTIN96)
Specify 0 or 1 to indicate whether read protection is to be set or
canceled. 1 for set and 0 for reset. When read protection is set, the
reading of all areas becomes restricted.
You must concurrently use an access password other than "00000000",
and for reset, specify the same number sequence as the access
password used during setting, in the cancellation password.
(dedicated for NXP G2XL)
Specify 0 or 1 as the value of the EAS bit. 1 for set and 0 for reset.
You must concurrently use an access password other than "00000000",
and for reset, specify the same number sequence as the access
password used during setting, in the cancellation password.(dedicated
for NXP G2XL)
Specify 0 or 1 to indicate whether read protection is to be set or
canceled. 1 for set and 0 for reset. When read protection is set, the
reading of all areas becomes restricted.
You must concurrently use an access password other than "00000000",
and for reset, specify the same number sequence as the access
password used during setting, in the cancellation password.
(dedicated for NXP G2im/G2iL)
Specify 0 or 1 as the value of the EAS bit. 1 for set and 0 for reset.
You must concurrently use an access password other than "00000000",
and for reset, specify the same number sequence as the access
password used during setting, in the cancellation password.(dedicated
for NXP G2im/G2iL)
Usually, for RFID write item without print data, only writing of RFID data
is performed, and the label is not fed. (Except for cases where the tag
offset is set to other than default.)
When "1" is specified in this parameter, the label is fed even if the
item does not contain print data.
When "0" is specified for this parameter, the label is not fed for the
item without print data, and the operation is the same as when fsw: is
not specified.
If don't feed, Short buzzer will sound 2 times when write is successful.
Short buzzer will the sound 6 times when it fails to write.
In addition, if 2 is specified for the item including print data, a write test
can be performed without consuming a label as only write is executed
without feed/print.
Valid range:0-2
Declare when executing conversion according to the code standard.
SSCC96 and SGTIN96 can be specified. If you specify 'a', it indicates
SSCC96, and if you specify 'c', it indicates SGTIN96.
The converted data is written in the EPC area. Therefore, you can no
longer use the epc: parameter identifier
Valid range: a, c
Specify the filter value with the number from 0 to 7. Refer to the filter
value standard table described later.
Specify the company prefix with a 6 to 12-digit decimal number.
In the case of SSCC96, specify the serial reference with a 5 to 11-digit
decimal number together with the number sequence specified in com:,
so that the value is 17 digits or less. Even if the value does not reach 17
digits, leave it as is since the upper digits are filled with a zero inside
the printer.
In the case of SGTIN96, specify the serial number with 12-digit fixed
decimal number. Specify 274877906943 or a smaller number.
It becomes a parameter error in the case of less than 12 digits.
Specify the item reference with a 1 to 7-digit decimal number together
with the number sequence specified in com:, so that the value is 13
digits or less.
Even if the value does not reach 13 digits, leave it as is since the upper
digits are filled with a zero inside the printer.
315