7.7.1.3
Status 4 (when CRC check is disabled)
CONNECT
DISCONNECT
Host
ENQ
(Status request command)
ID Number = [Space]
Status = "Waiting for receive"
Status
Remaining print q'ty = [000000]
Job name = [Space]
Print command (STX-ETX)
ID number = [05]
Print q'ty = 100
Job name = [SATO]
ACK
(Printer status: no error)
ENQ
(Status request command)
ID number = [05]
Status = "Editing"
Status
Remaining print q'ty = [000000]
Job name = [SATO]
ENQ
(Status request command)
ID number = [05]
Status = "Printing"
Status
Remaining print q'ty = [000100]
Job name = [SATO]
Print command (STX-ETX)
ID number = [06]
Printq'ty = 50
Job name = [SATO]
ACK
(Printer status: no error)
ENQ
(Status request command)
ID number = [05]
Status = Paper end
Status
Remaining q'ty number = [000098]
Job name = [SATO]
ENQ
(Status request command)
ID number = [05]
Status = "Printing"
Remaining print q'ty = [000098]
Status
Job name = [SATO]
~ ~
ENQ
(Status request command)
ID number = [05]
Status = "Printing"
Status
Remaining print q'ty = [000001]
Job name = [SATO]
(Status request command)
ENQ
ID number = [06]
Status = "Printing"
Remaining print q'ty = [000050]
Status
Job name = [SATO]
Printer
Receive/Analysis/Edit
Print operation
Print the 1st label
Print the 2nd label
Print the 3rd label
Print the 3rd label
~ ~
~ ~
Print the 100th label
Print the 1st label
573
Receive/Analysis/Edit
Paper end error