[Supplemental explanation]
1. This command can be used only once between the data transmit start <A> to the data transmit end <Z>.
2. When print data is to be included beside EPC code write, multiple labels can be specified. If there is no print data as
in Example 2, media is not fed. If a blank media is to be fed after EPC code write, specify feeding without print as in
Example 3.
] If print data is included,
[Example 1
<A>
<V>50<H>50<XM>0123456789ABCDEF01234567
<IP0>e:z,d:0123456789ABCDEF01234567;
<Q>1
<Z>
] If you specify EPC code write without print data, the media is not fed, and QTY cannot be
[Example 2
specified.
<A>
<IP0>e:z,d:0123456789ABCDEF01234567;
<Z>
] If there is no print data, but you have specified feeding without print in EPC code write, the
[Example 3
media is fed, and QTY can be specified.
<A><IP0>e:z,d:0123456789ABCDEF01234567,g:1; <Q>2<Z>
or
<A><IP0>e:h,epc:0123456789ABCDEF01234567,fsw:1;<Q>2<Z> (for the standard format)
When EPC code
write is successful
When EPC code
write has failed
* If you have set TAG OFFSET to other tan the default value, or if you have specified temporary tag offset,
feeding is performed in Example 2 as well.
3.The buzzer sounds as described below.
If an EPC code write that does not accompany print data is specified, the buzzer sounds to notify you whether the
EPC code write succeeded.
EPC code write successful: Two short beeps
EPC code write unsuccessful: Six short beeps
Note that the buzzer sounds for EPC code write success or failure vary depending on the "Sound" > "Error Sound"
settings in the System menu.
4. Unused parameters can be omitted.
5. For details on the filter value to be used with SSCC96/SGTIN96, refer to the table below according to the purpose of
use.
Filter value standard table
Filter value
0
1
2
3
4
5
6
7
the QTY can be specified.
Example 1
Print, feed
Two short beeps
Print tag error
Six short beeps
Retry operation
SSCC96
All Others
Reserved
Full Case for Transport
Reserved
Reserved
Reserved
Unit Load
Reserved
320
Example 2
Example 3
Don't feed
Feed a blank label
Print tag error
Retry operation
SGTIN96
All Others
Point of Sale (POS) Trade Item
Full Case for Transport
Reserved
Inner Pack Trade Item Grouping for
Handling
Reserved
Unit Load
Unit inside Trade Item or component
inside a product not intended for
individual sale