14.6 Memory Card
14.6
ESC+&S Form Overlay Registration
Form Overlay Registration
Form overlay registration
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying the registration of fixed print contents to a memory card.
[Format]
<&S>,aa(,bbbb,ccccc)
●Parameter
a [Registration No.]
b [Size specification of window width]
c [Size specification of window height]
[Coding Example]
<A>
<V>100<H>100<X21>,MODEL
<CC>1
<&S>,1
<Z>
[Supplementary Explanation]
1. Specify slot No. with Card Slot for Use <CC> prior to this command.
2. Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with the format to be registered.
3. Registration of identical registration No. is invalid.
4. Both Print of Graphic <G> and Print of BMP File <GM> can be registered.
5. This command<&S> allows up to 99 registries. Note that the capacity of registry may vary depending on the
memory card to be used.
6. Data registered with this command<&S> can be cleared with Clear <*>R.
7. The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
Do not turn off the printer while accessing the memory. There is no guarantee of data in media if the power is turned
off while accessing the
[Valid Range]
Model
203 dpi
CL4NX
305 dpi
609 dpi
203 dpi
CL6NX
305 dpi
(*1) Valid range for "Standard" in "Head Base Position" setting.
(*2) Valid range for "Left-justify" in "Head Base Position" setting.
Refer to the operator manual for further information of the setting.
&S
<26>
<53>
16
16
=
Valid range:
=
Valid range:
=
Valid range:
memory.
Horizontal size of the window
50 to 832
50 to 1248
50 to 2498
50 to 1216 (*1)
50 to 1340 (*2)
50 to 1984 (*1)
50 to 2010 (*2)
ESC+&S
Parameter
,aa(,bbbb,ccccc)
The registered data becomes valid.
The registered data is valid until the next specification is made.
The registered data is valid until the next specification is made.
1 to 99
Refer to the table below (Omissible)
Refer to the table below (Omissible)
Valid Range (dot)
Vertical size of the window
286
50 to 20000
50 to 18000
50 to 9600
50 to 20000
50 to 18000