Esc+Tu Printing Tag Data(Iso/Iec14443 Typea) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

16.11 RFID
16.11
ESC+TU
Printing Tag Data
Data(ISO/IEC14443 TypeA)
(ISO/IEC14443 TypeA)
Command
ESC
HEX code
<1B>
16
Default Value
Nil
When turning off the power switch
Valid range and
Valid range within item
term of
command
Valid range between items
[Function]
Reads UID data from NTAG or MIFARE tag and develops to specified direction to make it possible to print on label.
[Format]
<TU>a(,n~n)
●Parameters
a
= To use this functionality or not
n = ID converted to a UID in the data area of each UID command (only when a = 1)
Character size: 4-16 bytes
Character type: Any (Alphanumeric)
(All parameters should be in the ASCII format)
[Coding Sample] A sample using SATO as ID.
<A>
<RK>4,D0,,df2:FFE0
<TU>2,SATO
<%>0
<V>0410
<H>0090
<P>00
<L>0101
<XM>SATO
<%>0
<V>0060
<H>0040
<D>102120*SATO*
<%>0
<V>0195
<H>0055
<P>00
<L>0101
<XM>*SATO*
<%>1
<V>0595
<H>0520
<D>102060*SATO*
<TU>0
<%>1
<V>0595
<H>0035
<P>00
<L>0101
<XM>SATO
<Q>00001
<Z>
Printing
Tag
TU
Parameter
<54>
<55>
a(,n~n)
16
16
The set command is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter becomes invalid.
2: Read UID data and start using
(Declare the 14-digit UID by using the 2.)
0: Cancel use
374
ESC+TU

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents