Parameters related to configuration for authentication (omissible)
lma:
Set address for password-lock
prt:
Set protection format
acl:
Lock authentication configuration
information
Set number of retries for
lim:
authentication
Parameters related to access password(omissible)
apw:
Access password
Set data to return when
pck:
password confirmation is
successful
psw:
Specify unlock password
sa0:
Access restriction area
sa1:
Access restriction method
sak:
Specify access password
aky:
Specify unlock password
Parameters related to feed control(omissible)
fsw:
Specify feed without printing
Sets the address to the block that requires password check.
Valid range: 0-255, 3-digit decimal
A parameter error will occur if a value exceeding specified inlet capacity is
specified.
IC
Chip
Product
type
00
NTAG203
01
NTAG210
03
NTAG213
04
NTAG215
05
NTAG216
30
MIFARE Ultralight
31
MIFARE Ultralight(EV1)(MF0UL11)
33
MIFARE Ultralight C
62
my-d move NFC
-:No password
*:my-d move NFC is excluded because it is applied to a fixed area
Sets the type of restriction.
Valid range:0-1
0: write protect
1: read-write protect
Note: When designated for my-d move NFC, regardless of set value this
setting:
(1) Cannot be cancelled
(2) "dlk" cannot be used
Locks authentication configuration except for password.
Unlockable after locking.
Perma-lock is implemented when 1 is specified.
Nothing is implemented when 0.
Valid range: 0 to 1
Sets number of retries when password authentication fails.
Valid range: 0-7
Note: When set to 7 or multiple instances add up to 7 or more with my-d
move NFC, setting cannot be changed.
Specify an 8-digit fixed hexadecimal when you want to lock/read-protect with
password.
Specify a 4-digit fixed hexadecimal data to return when the password check is
successful
Specify the same numerals used to lock the area which is password
locked/read-locked.
Specify a 2-digit fixed decimal within 00-35 for the block to protect, dedicated
for MIFARE Ultralight C.
Specify the contents of restriction dedicated for MIFARE Ultralight C.
00: read-write protect
01: write protect
Specify a 32-character fixed hexadecimal when locking/read-protecting with
password, dedicated for MIFARE Ultralight C.
Specify the same numerals used to lock the area which is password
locked/read-locked, dedicated for MIFARE Ultralight C.
Normally, RFID write print jobs that don't include print data writes but don't
feed label.(Except for cases with tag offset as default)
When 1 is specified for this parameter, even the print jobs that don't include
print data will feed.
When 0 is specified, print jobs that don't include print data will not feed, which
is the same as not specifying fsw:.
Also, printer only writes without feeding or printing when 0 is specified for
print jobs that include print data, which allows write test without having to
waste label.
If don't feed, Short buzzer will sound 2 times when write is successful. Short
buzzer will the sound 6 times when it fails to write.
In addition, if 2 is specified for the item including print data, a write test can be
performed without consuming a label as only write is executed without
feed/print.
Valid range:0-2
364
Valid
addres
-
0 to 11
0 to 35
0 to 123
0 to 221
-
0 to 11
-
(*)