SATO CL4NX Programming Reference Manual page 329

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

6. SSCC96 code conversion
This function is used to generate a code according to the SSCC96 standard when a company prefix, serial reference,
and filter value are applied. For the time being, the usage method is explained by using an example in which the
following numbers have been applied. All numbers are in decimals.
Company prefix: 4011661
Serial reference: 3000000001
Filter value: 0 (Select the filter value from the filter value standard table described earlier according to the purpose
of use. In this example, the filter value is 0 from "All Others")
According to the standard, the company prefix and serial reference are combined together to result in 17 digits. Of
these 17 digits, the proportion of the company prefix and the serial reference can be selected from the seven
combinations described in the table below.
Partition value
Number of digit of the company prefix
0
1
2
3
4
5
6
In the case shown in this example, the following combination is assumed:
Number of digits of the company prefix: 7
Number of digits of serial reference: 10
The partition value is 5, but since this value is generated within the PC, it need not be specified.
Under this condition, if the format of EPC code write <IP0> is applied, it results in the following:
When the standard format is used
<IP0>e:h,enc:a,com:4011661,srl: 3000000001,flt:0;
Description of each parameter
e:h,------------- Specifies the standard format
enc:a------------ Specifies SSCC96 code conversion
com:4011661,----- The company prefix is 4011661
srl:3000000001,-- The serial reference is 3000000001 17 digits when combined with com:
flt:0 ----------- The filter value is All Others
;---------------- End terminal
When the one-character parameter identifier in the conventional format is used
<IP0>e:a,c:7,s:10,f:0,d:40116613000000001;
Description of each parameter
e:a,-------------- Specifies SSCC96 code conversion
c:7,-------------- The company prefix is 7 digits
s:10,------------- The serial reference is 10 digits 17 digits when combined with c:
f:0,-------------- The filter value is All Others
d:40116613000000001 –Number in which the company prefix and serial reference are joined together It is
;---------------- End terminal
When
these commands
3114F4DA34B2D05E01000000 and 24 characters (18 characters in actuality), and are written in a tag.
12
11
10
9
8
7
6
17 digits.
are
executed,the
above
321
Number of digits of the serial reference
5
6
7
8
9
10
11
parameters
are
converted
to
SSCC96
code

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx