SATO CL4NX Programming Reference Manual page 450

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[Exception processing]
Exception condition
Parameter name
A value outside the range is specified
Identifier
Command error
Terminology
Description
Command error
The data received after a command error is
determined is not considered as a parameter of
this command.
[Coding sample1]
<A>
[DC2]PJ,U1,NO
<Z>
(Specify EPC area)
[Coding sample2]
<A>
[DC2]PJ,U2,RS
<Z>
(Specify RSSI to TID area readout and option)
[Coding Sample 3]
[DC2]PJ,U1,U2,NO (Specifies EPC and TID area read)
[DC2]PJ,U3,U4,MT (Reads USER and PC/AFI area and specifies module temperature to option)
[Return status/ Format]
cc:d...d(,cc:d...d)
Symbol
Identifier
c
Data
d
[Sample of status reply1]
■When EPC data"E0123456789ABCDEF0123456" is on Gen2 supported tag
[STX]24,E0123456789ABCDEF0123456[ETX]
■ When Gen2 supported tag fails to read EPC data
[STX]11,EPC_Tag_Err[ETX]
[Sample of status reply 2]
When TID data "E200680612345678"is on Gen2 supported tag and RSSI is 10dBm
[STX]22,E200680612345678,RS:10[ETX]
[Sample of status reply3]
■To get both EPC and TID when EPC data "E0123456789ABCDEF123456" and TID data "E200680612345678" are
recorded
[STX]47,EP:E0123456789ABCDEF0123456,TI:E200680612345678[ETX]
[Sample of status reply 4]
■When failed to read EPC data that supports Gen2 tag
[STX]11,EPC_Tag_Err[ETX]
Name of Parameter
442
Description
EP:EPC area
TI:TID area
UD:USER area
PC:PC/AFI area

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents