10.16 2D code
10.16

ESC+QV QR Code Version

QR Code Version
ESC
Hexadecimal
code
<1B>
16
Initial value
aa=00
When the power switch is OFF
Valid range and
Valid range within items
term of
command
Valid range between items
[Function]
Specifying any QR code version can print the code with fixed cell size.
When not specified, it becomes the auto setting.
[Format]
<QV>aa
●Parameter
aa[Version number]
=Valid range
An errormay arise for some QR code types, while analyzing the image.)
Print valid MODE1
[Coding example 1]MODEL 1, Error correction: H, Cell size font: 05, Manual setting, Normal mode, Version 14
<A>
<V100><H100><2D31>,H,05,0,0
<QV>14
<DN0011>,0123456789X
<Z>
[Coding example 2] MODEL 2, Error correction: H, Cell size font: 05, Manual setting, Normal mode,Version 35
<A>
<V100><H100><2D30>,H,05,0,0
<QV>35
<DN0011>,0123456789X
<Z>
[Coding example 3] MicroQR, Error correction: L, Cell size font: 05, Manual setting,Version M3
<A>
<V100><H100><2D32>,H,05,0
<QV>3
<DN005>,01234
<Z>
[Supplemental explanation]
1. MODEL 1: up to 17, MODEL 2 up to 40, MicroQR: up to 4
The valid parameter range is from 0 to 40 and it varies depending on the QR code type.
2. For MicroQR, 1 to 4 correspond with M1 to M4.
3. Specifying <QV> 0 becomes Auto. (Default: Compatible with the existing code)
4. Sending the data exceeding the data size of specified version will result in error and QR code will be not
printed.
5. Specify the <QV> command in between <2Dxx> and <DN>/<DS>.
6. It doesn't affect other than QR code.
7. When resulted in a parameter error, it will be handled in the same manner of no specification.
[About the version]
Refer to the QR code specification for details.
Version 1: 21 x 21 cell, Version 2: 25 x 25 cell, ..., Version 40: 177 x 177 cell.
For MicorQR, M1 to M4 = 11 x 11 to 17 x 17 cell, smaller than MODEL 1/2.
QV
Parameter
<51>
<56>
aa
16
16
The set parameter is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter becomes a default value in the next
item <A>.
: 00 to 40 (Specifying this range doesn't become a parameter error.
: 00 to 14 (00: Auto setting)
MODE2
: 00 to 40 (00: Auto setting)
MicroQR : 00 to 04 (M1 to M4) (00: Auto setting)
245