SATO CL4NX Programming Reference Manual page 397

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

Detailed parameters of NFC(NDEF) support (omissible)
dnm:
Device name
dcl:
Class of Device
scl:
Service Class UUID
rfb:
RF Bands
ssi:
SSID
nky:
Network Key
atp:
Authentication Type
For ndf:4 or ndf:5 ~ 6 (wcc:1), specify the device name.
Specify a string within 16 characters from 0~9, A~Z, a~z, - (hyphen) and _
(underscore).
For ndf:4, specify the device class to a fixed 6-digit hexadecimal.
※ Considering the extensibility of the function, only the digit number is
checked instead of its content.
Specify service code for the first 2 digits (refer to "Service code of the device
class" table in 16.10(14443 TypeA<RK>)).
Specify major device class for 3, 4 digits and the last 2 digits for minor device
class (refer to "Major device class and minor device class of the device class"
table in 16.10(14443 TypeA<RK>)).
E.g.
dcl: 400204
Service
code:
Major device
class
For ndf:4, specify more than 1 service class (refer to "Service class") in
16.10. (14443 TypeA<RK>).
Specify to hexadecimal which digit is 4's multiples.
※ Considering the extensibility of the function, only the digit number is
checked instead of its content.
E.g.
scl:111E110B
The first
The second
service class
Up to 8 service classes can be specified.
For ndf:5~6, specify the wireless frequency band when using Wi-Fi to a fixed
2-digit hexadecimal.
Value
Encryption type
01
2.4GHz
02
5.0GHz
04
60GHz
For ndf:5~6, specify the recognition name of the access point to 1 ~ 32 digit.
Usable characters are 0~9, A~Z, a~z and the following symbols:
!
"
#
$
%
&
;
<
=
>
?
@
※Space cannot be used.
The size information of the front data delimited by a comma is necessary. For
example if the data size is 32, specify as ssi:32,abcde...
For ndf:5~6, specify the network key of the access point to 8 ~ 63 digit.
Usable characters are 0~9, A~Z, a~z and the following symbols:
!
"
#
$
%
&
;
<
=
>
?
@
※Space cannot be used.
The size information of the front data delimited by a comma is necessary. For
example if the data size is 8, specify as nky:8,AbCdEfGh.
For ndf:5~6, specify the authentication type of the access point to a fixed
4-digit hexadecimal.
Valid range: 0001~FFFF (refer to "Setting value of the authentication type"
table in 16.10(14443 TypeA<RK>)).
※ Considering the extensibility of the function, only the digit number is
checked instead of its content.
389
Minor device
class
service class
'
(
)
*
+
,
[
\
]
^
_
`
'
(
)
*
+
,
[
\
]
^
_
`
-
.
/
:
{
|
}
~
-
.
/
:
{
|
}
~

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents